by engineering | May 23, 2019 | FAQ General-Group
It seems to be earlier as summer approaches. Question: I’ve noticed a problem with our single axis tilt tracker that we replaced. It’s begun reaching 45 degrees west earlier and earlier in the day rather than later, which you would expect going into summer. A recent...
by engineering | Nov 9, 2017 | FAQ General-Group
FAQ Corresponding Terminal No. to LED Terminal No. Type LED No. 1 DI0 1 31 DI1 2 2 DI2 3 32 DI3 4 3 DI4 5 33 DI5 6 4 DI6 7 34 DI7 8 5 DI8 9 35 DI9 10 6 DI10 11 36 DI11 12 7 DO0 1 37 DO1 2 8 DO2 3 38 DO3 4 9 AI0 1 39 AI1 2 10 AI2 3 40 AI3 4 11 AI4 5 41 AI5 6 12 AI6 7...
by engineering | Sep 29, 2017 | certified template-group, FAQ General-Group
General Category The Tracker IPm currently can control 2 axis’ simultaneously. These can be 1 Elevation & 1 Azimuth or 2 Elevation....
by engineering | Sep 29, 2017 | certified template-group, FAQ General-Group
General Category The Tracker IPm uses the NREL Solar Positionin ALgorithm which calculates the sun’s position based on Latitude, Longitude, elevations and time of day. This calculation is compared to a feedback from an inclinometer for the Zenith Elevation and a...
by engineering | Sep 29, 2017 | certified template-group, FAQ General-Group
General Category If your design has the controller and relays at some distance from the motor and you will be running the risk of diminished voltage of the DC power as the distance increases. There are very good Voltage Drop Calculators on the web such...