by engineering | Oct 28, 2019 | 2400 Wiring Diagram-Group
135 (VT-MIPM-135 SPA) Supports 2 Altitude & 2 Azimuth or 4 Azimuth or 4 Altitude Masters Wiring Diagrams - Series 2400 MX-1122PA SOURCING (factory default) AX1 Azimuth or Altitude – Digital Pulse Input (Hall Effect) 2 motors AX2 Altitude – Analog...
by engineering | Oct 28, 2019 | 2400 Wiring Diagram-Group
Series 2400 Selectable 1x / 2x Wiring Diagrams - Series 2400 Click to enlarge More on Sinking/Sourcing...
by engineering | Oct 28, 2019 | 2400 Wiring Diagram-Group
Series 113-213 (Sinking) Series 2400 Selectable 1x / 2x Wiring Diagrams Click to enlarge More on Sinking/Sourcing...
by engineering | Oct 27, 2019 | Product Specifications-Group
Product Applications: Solar Tracker Remote I/O Specifications 32 Discrete Output ChannelsOutput voltage range 10-30 VDCMax. output power: 0.5 Amps per channel, 8A per moduleMax. off state leakage: 0.01 mA (less than 10 uA)Short circuit protection: self-reset fuses...
by engineering | Oct 27, 2019 | Product Specifications-Group
Product Applications: Solar Tracker Remote I/O Specifications Discrete Input ChannelsVoltage range : 10 – 30 VDCInput Polarity: Sourcing (apply power to active) or sinking (ground closure) on 8 inputsGuaranteed ON voltage: 9 VDCGuaranteed OFF voltage: 5.0...