Series 1200 Controls
The Alarm module will generate alarm codes and write them to analog outputs as they are encountered. The highest level of multiple alarms will be displayed. All alarms will be totaled and displayed.

 

Register Description
AlarmCode_AL Numeric alarm Code for motor #1
AlarmCode_AZ Numeric alarm Code for motor #2
AlarmsTotal Total Combined Alarms for both axis
1 – In Hard Manual Mode – switches in neutral

2 – Hold Motor # 2-No Simultaneous Motor Runs

3 – Encountered Physical Max LS

4 – Encountered Physical Min LS

5 – Encountered Soft Max Limit in HARD Auto

6 – Encountered Soft Min Limit in HARD Auto

7 – Motor Reversal Timer Hold

8 – Motor Run Timer Hold

9 – Hall pulses not detected in last motor run

10 – Emergency All Control Outputs Disabled

11 – Over-ride everything – stow tracker

12 – Wind Exceded High Limit

13 – Wind Exceded High-High Limit

14 – No inclinometer defined

15 – No inclinometer detected

16 – Single Axis Configuration Motor 2 Disabled

50 – Serious Hall failure in both directions